Description
Purpose
Toxfree Marine Plus XOxZ1-K (AS+) and XOxTCuZ1-K (AS+) - halogen-free cables are safety, instrumentation and communication cables. They are fire resistant and specially designed for to continue data/signal transmission in case of fire. Therefore, their use is recommended for public spaces and marine applications.
• For marine use.
• For public use.
Construction
Conductor
Electrolytic annealed copper conductor, class 5 (flexible), according to standard EN 60228 (conductor resistance according to standard IEC 60092-376, table 6).
Insulation
Mica tape + cross-linked polyethylene insulation, type HF XLPE 90 °C, according to standard IEC 60092-360.
The standard identification of insulated conductors is as follows: 2 × pair numbered
(white + blue).
Other colors available on request.
Strand assembly
Twisted conductors in pairs.
Single shielding (XO3Z1-K and XO3TCuZ1-K)
Aluminum + polyester tape with 100% coverage + tinned copper drain wire installed over assembled conductors.
Pair assembly
Twisted in concentric layers.
Total protection
Aluminium + polyester tape with 100% coverage + tinned copper drain wire installed over assembled pairs.
Braided shielding (XO2TCuZ1-K and XO3TCuZ1-K)
Tinned copper wire braid screen over common screen.
Outer sheath
Low Smoke Halogen Free (LSHF) thermoplastic polyolefin sheath, type SHF1, according to standard IEC 60092-360.
Orange color, non-toxic, flame retardant and fire resistant.
| XO2TCuZ1-K (AS+) | ||||
|---|---|---|---|---|
| Cross-section (mm²) |
Diameter (mm) |
Weight (kg/km) |
Outdoor (A) 1 |
Resistance at 20ºC (Ω/km) |
| 1 x 2 x 0.75 | 8,3 | 100 | 17,1 | 27,6 |
| 2 x 2 x 0.75 | 11,6 | 145 | 13,7 | 27,6 |
| 4 x 2 x 0.75 | 14,9 | 215 | 11,2 | 27,6 |
| 7 x 2 x 0.75 | 20,1 | 335 | 9,2 | 27,6 |
| 10 x 2 x 0.75 | 22,5 | 495 | 8,6 | 27,6 |
| 14 x 2 x 0.75 | 23,7 | 585 | 7,4 | 27,6 |
| 19 x 2 x 0.75 | 26,5 | 745 | 6,5 | 27,6 |
| 24 x 2 x 0.75 | 31,3 | 945 | 6,5 | 27,6 |
| XO3TCuZ1-K (AS+) | ||||
|---|---|---|---|---|
| Cross-section (mm²) |
Diameter (mm) |
Weight (kg/km) |
Outdoor (A) 1 |
Resistance at 20ºC (Ω/km) |
| 2 x 2 x 0.75 | 13,1 | 180 | 13,7 | 27,6 |
| 4 x 2 x 0.75 | 15,3 | 255 | 11,2 | 27,6 |
| 7 x 2 x 0.75 | 18,8 | 425 | 9,2 | 27,6 |
| 10 x 2 x 0.75 | 22,3 | 545 | 8,6 | 27,6 |
| 14 x 2 x 0.75 | 24,4 | 680 | 7,4 | 27,6 |
| 19 x 2 x 0.75 | 27,3 | 905 | 6,5 | 27,6 |
| 24 x 2 x 0.75 | 34,3 | 1.180 | 6,5 | 27,6 |
¹ Reference method E according to IEC 60092-352 and IEC 60364-5-52 in open air at 30°C ambient temperature.
For cables having more than 1 unit a factor is applied according to the Table A6 of the IEC 60092-352 standard